Fertilizer rate, Setting the fertilizer adjuster – Great Plains 2525P Material Rate User Manual

Page 65

Advertising
background image

10/19/2010

118-960B

Great Plains Mfg., Inc.

65

Fertilizer rate is controlled by:

• Rate adjuster setting

Fertilizer rate is independent of the Drive Type used for
main seed box planting.

Before setting the rate, raise the drill and rotate the
gauge wheels. Check that meters, tubes and drives are
working properly and are free from foreign material.

The procedure for setting the fertilizer rate is:

1.

Know your material density. If it is substantially differ-
ent from the material used to generate the charts,
apply a correction factor before selecting the initial
rate from the charts.

2.

Consult the fertilizer rate chart for desired applica-
tions density (pounds/acre or kg/hectare). The chart
provides the initial adjuster setting.

3.

Configure the adjuster on one or both sides of the
drill.

4.

Calibrate the drill for your specific material.

5.

Set both rate adjusters identically.

Setting the Fertilizer Adjuster

Refer to Figure 5
Each fertilizer box has its own adjuster, located near box
center. Position the adjuster to the rate from the fertilizer
Chart in the Seed Rate manual.

To adjust:

1.

Rotate the adjuster knob located to the right of the
scale

. Rotate counter-clockwise to increase rate.

The knob stays at your setting due to springs clamp-
ing a nut at the left end of the shaft.

2.

Rotate the adjuster until indicator

is about 10 past

the desired value, then move it back to the desired
value.

1

2

Agricultural chemicals can be dangerous. Improper use can
seriously injure persons, animals, plants, soil and property.

• Do not use liquid treatments with drill.

• Read and follow chemical manufacturer’s instructions.

• Wear protective clothing.

• Handle all chemicals with care.

• Avoid inhaling smoke from any type of chemical fire.

• Never drain, rinse or wash dispensers within 100 feet

(30m) of a freshwater source, nor at a car wash.

• Store or dispose of unused chemicals as specified by

chemical manufacturer.

• Dispose of empty chemical containers properly. Laws

generally require power rinsing or rinsing three times,
followed by perforation of the container to prevent re-
use.

1

2

Figure 5

Fertilizer Rate Adjuster

Fertilizer Rate

Advertising