Great Plains Yield-Pro 1625 Planter 2004 User Manual

Page 8

Advertising
background image

402-188M

12/12/2005

Great Plains Mfg., Inc.

Base Update 2005 Kit

8

Refer to Figure 13

16. Place seed strainer grate weldment (2) in seal

holder weldment (3).

17. Peel release paper from back of meter top seal

(1). Stick seal (1) on seal holder weldment (3).

18. Measure distance from top of meter top seal

(A) to top angle on manifold (B). NOTE : See
Figure 6 on page 5. Make sure new seal (1) is
replaced at same height as old seal.

Figure 13

Top Seal

23464

Figure 12

Seal Holder Weldment

Refer to Figure 12

13. Slide previously removed corner seal mount

weldments (3) along front corners between
top of manifold (1) and seal holder weldment
(2).

14. Attach new seal holder weldment (2) to new

manifold top weldment (1) using 1/4-20 x 5/8
bolts, 1/4 flat washers, 1/4 lock washers, and
1/4-20 hex nuts.

15. Secure corner seal mount weldments (3) to

manifold top weldment (1) and seal holder
weldment (2). Use 1/4-20 x 1 bolts , 1/4 flat
washers, 1/4 lock washers, and 1/4-20 hex
nuts. Attach top corner seals to corner seal
mount weldments. NOTE: Top of corner
seals need to be 1.19" above top of main
seal.

Install Fan Inlet Rain Shield

Refer to Figure 14

1.

Attach fan inlet rain shield (1) to outside of
fan using four #12-14 x 3/4 hex head
screws (2).

NOTE: Shield should overlap intake screen
mounting plate against fan housing.

23417

Figure 14

Fan Inlet Rain Shield

23462

Advertising