Section 2: Hydraulics

3/11/2004

Series I UT3030-UT5052 Ultra Till 786-026M

41

5-Section Ultra Till Hydraulic Down Pressure Preparation and Setup

Note: This setup procedure is for tractors with closed-center or pressure compensated flow
hydraulic systems. For open-center hydraulic systems contact your dealer for instructions.

1. Adjust the bypass valve by turning knob

(1), Figure 2, clockwise all the way in and
then backing out 1 full turn.

2. On tractor, adjust flow-control valve to low

side of flow rate. NOTE: The faster the
flow of oil through the system the greater
potential for oil heating, premature wear
or tractor damage.

3. Lock the fold hydraulic lever for

continuous downward oil flow.

4. Adjust pressure reducing valves knob (2

& 3) on implement so the pressure
gauges reads 1200 psi each. Never
exceed 1400 psi.

5. While watching pressure gauges, slowly

open bypass valve, knob (1) until gauges
reads around 1100 psi. Pressure might rise

and then fall off as knob is opened. If
pressure exceeds 1400 psi during this step,
the tractor flow is too high, reduce tractor
flow. Lock bypass valve knob (1) at 1100 psi.

6. Finally adjust valve knobs (2 & 3) to the

desired wing down pressure setting of 400 to
700 psi. Never exceed 900 psi.

7. In field operation, Lock the fold

hydraulic lever for continuous
downward oil flow. If wings are
running too high, increase pressure
setting to the appropriate valve, knob
(2 or 3), to level machine. If center is
too high, decrease pressure setting
with knob (2) on Inside wing valve.

Figure 2

Advertising