Refer to Figure 15 (some components shown exploded for
clarity - never remove any except the outlet cap).
A71 Liquid Level Float Gauge:

Check this gauge when accepting a tank. It needs
to be in sound mechanical condition, legible, and
reading no higher than 85.

This gauge has a mechanical float that is coupled to
the indicator needle. Float gauges typically report
0-100 percent of fill.

Float gauges are typically mounted at tank top,
facing up, but may also be installed at 45

°, with face

tilted up, or horizontal, with face to front or side.

On a leased tank, learn the reading to expect when
the tank level reaches minimum-usable. It may be
an indication above, at, or even below zero.

The gauge reading may be inaccurate if the tank is
on a slope, or has just been moved (due to
sloshing).