OPERATOR’S MANUAL

IntelliAg PDC User Level 1 (GP)

11001-1508-200903

SYS INFOR AND DIAGNOSTICS / 15

IO IMP LIFT

NOTE: If the values are reversed and

the value displays a “1” when
the implement is raised, the
wiring for the implement switch
will need to be reversed so that
an accurate readout is
achieved.

The IO Implement Lift value displays the current state of the implement
status switch. This value will be “1” when the implement is down. The value
will be “0” when the implement is raised.

APP ID

Hardware identification only. Not applicable to the end user.

SOL PWR VOLT

The Solenoid Power Voltage value displays the detected solenoid power
voltage. This voltage level is the high current voltage leg of the system
which is used to power high current solenoids and valve actuators. This
value will generally be equal or nearly equal to the tractor battery voltage.

ECU PWR VOLT

The Electrical Control Unit (ECU) Power Voltage value is the detected ECU
voltage. This voltage level is the low current voltage leg of the system and is
used to power modules and sensors. This value will generally be equal or
nearly equal to the tractor battery voltage.

SNSR PWR VOLT

The Sensor Power Voltage value is the detected output voltage to the seed
sensor on the Working Set Master (WSMT) module. This value is typically
+8 VDC.

GND VOLT

If the system is properly grounded, this value is typically 2.50V on software
versions older than 2.7. Software versions newer than 2.7 and WSMT
software is 0V.

DIAGNOSTICS MANUAL VALVE POSITION

Manual opening of a selected channel’s valve is used for calibration or
troubleshooting purposes in the case of system failure.

Press the Diagnostics button to access the Diagnostics screen.

1. The Diagnostics screen will show Channel 1 as a default.

– If a channel other than Channel 1 needs to be selected, press the

Next Channel button until the appropriate channel displays. The
Next Channel
button only displays when more than one channel is
configured.

MANUAL OPEN OF CHANNEL

1. Press the Enable Manual Valve button to run the current selected

channel. This allows for manual open and close of valve position.

IMPORTANT: The Enable feature will only operate on the Diagnostics

screen.