Treatment Meter Gate Calibration
(Option)

Perform treatment meter gate calibration seasonally, or
whenever one or more rows appears to be metering at a
rate inconsistent with the dial setting.

Refer to Figure 82
Note: This calibration requires the 403-043V tool

, one

or more of which was supplied with a planter
originally ordered with the treatment hopper option.
If you do not have this tool, you may be able to
substitute a hardened steel rod or length of straight
music wire 1.3 mm (0.051 inches) in diameter, held
vertically.

1.

Clean out the treatment hopper, per page 81. Secure
the lid on the hopper, and while the hopper is still
dismounted, invert it on a stable flat surface.

2.

Turn the meter knob

until the dial reads “

10

”.

3.

Loosen the two hex head screws

that secure the

meter gate ( , not visible in figure, shown in gray).
The gate is a polymer plate with a

∇-shaped opening

under the slotted gate retainer.

4.

Insert the small rod end of the tool

into the meter

gate opening.

5.

Re-adjust the dial to “

04

”.

6.

Slide the gate

into firm contact with the tool rod.

7.

Secure the hex head screws

.

8.

Remove the tool. set the dial to “

00

”. Re-install the

hopper on the row.

Material Application Risk:
Meter gate calibration is not the same as treatment rate
calibration. See the Seed Rate Manual for details of rate
calibration.

1

3

3

2

4

Figure 82

Treatment Meter Gate Calibration

34454

Chemical, Dust and Fume Hazard:
Wear a respirator, chemical gloves, and any other protective
equipment specified by the treatment supplier. Without gloves,
skin contact is likely. Skin contact is harmful or fatal with some
pesticides and herbicides Expect dust and fumes during
hopper removal and inversion.

If meters are not at “

00

”, beware of flowing material below

treatment delivery tubes. Material can flow when parked.

1

2

3

4

1

4

3

Advertising