Pre-assembly preparation, Remove existing components, Dismount valve and strainer – Great Plains Ground Drive Fertilizer Pump Yield Pro Planters User Manual

Page 2: Caution

Advertising
background image

Great Plains Mfg., Inc.

2

Ground Drive Fertilizer Pump

407-149M

04/23/2007

Pre-Assembly Preparation

Refer to Figure 2,
which depicts the planter with row units removed for clarity.

The ground drive pump is installed on the left wing,
at or near the location of the existing shaft-driven
fertilizer pump.

1.

Unfold the planter. The planter must be raised for
unfolding, but may be raised or lowered for all
tasks prior to Step 28. If left raised, installed lift/
transport locks. Secure the tractor.

2.

Flush the existing fertilizer system with water. Flu-
ids will drain off during updates to the plumbing.

!

CAUTION

Exercise caution when working with a used fertilizer system.
The chemicals are usually very caustic. Unless you fully
operate the planter while flushing with water, some chemicals
will drain from components during disassembly. Trace
amounts may remain in any case.

Remove Existing Components

Dismount Valve and Strainer

Refer to Figure 3

3.

Loosen the hose clamp

on the inlet port of

valve

and disconnect the hose

.

Remove and save:

CLAMP WRM DRV #16 SS (.68-1.5)

If the hose can reach the ground, protect the open
end from contamination, for example, by clamping
a plastic bag over the end. If the strainer

is due

for maintenance, this is an ideal time to clean it.

4.

Loosen the hose clamp

on the outlet port of

strainer

and disconnect the hose

.

Remove and save:

CLAMP WRM DRV #16 SS (.68-1.5).

Protect hose end from contamination.

5.

Remove:

AD 1 1/2MNPT X 1HB POLYPROP

plastic adaptor fitting from the inlet of valve

.

This fitting is not re-used.

6.

Remove the fasteners (not shown) that attach
valve

to valve mount plate

, and that attach

the plate to the planter frame.
Remove and save the valve/strainer assembly:

STRAINER BANJO LST150-80 MESH
VALVE 1 1/2FNPT BALL POLYPROP

and its interconnecting and outlet fittings.
The plate

and the fasteners are not re-used.

U

D

F

B

L

R

Figure 2

Location of Components

25303

U

D

F

B

L

R

Figure 3

Dismount Strainer

25304

70

56

67

1

2

56

69

52

56

67

1

56

70

56

70

2

56

69

67

67

52

70

67

52

Advertising