Quick Setup Guide for IntelliAg Model 3PYP 24 Row Twin Row Air Pro

11001-1528A-201209

©2012 DICKEY-john Corporation

Specifi cations subject to change without notice.

TABLE G:

Speed

Set

Default Value/

Value to Enter

Instructions/Defi nitions

Source

Digital Frequency

Select CAN Ground if radar is connected to ISO tractor cab harness. Select

Digital Frequency if radar or hall-effect is connected to WSMT actuator harness.

Gspd Constant

12192

Input based on pulse count produced by the ground speed sensor over 400’

distance. See Operator’s manual for calibration instructions.

Shutoff Speed

0.5 mph

Set desired minimum ground speed allowed before the system shuts off.

Minimum

Override

2.0 mph

Set to operate when actual ground speed falls below the designated value.

Control will operate at this speed until actual ground speed rises above mini-

mum override speed or actual speed drops below shutoff.

Master Sw

Timeout

10

Set to desired number of seconds system shuts off if the master switch is

turned on and there is no ground speed. Toggle master switch to restart the

system and turn off alarm.

Gspd Fail Alarm

Delay

5

Set to desired number of seconds alarm sounds after the ground speed is zero

and seed fl ow continues. (Monitor only)

Precharge

Ground Speed

0

Set to the desired speed the system will use when a precharge time has been

enabled for a control channel. Refer to Table C1: Planter Control Setup for

Precharge Time. This setting will only display when a Precharge Time has been

entered.

Implement Lift

Enabled

Implement lift switch, when enabled, displays an implement lift indicator on

the Main Work screen indicating implement lift position as up or down. Control

channels can be turned on and off without using the master switch.

STEP 9: Speed Set Calibration Setup

At the Main Work screen, press the Speed Set button

.

Enter desired values using Table G as reference.
Press the Work Screen button

when ground speed calibration

confi gurations are complete to return to the Main Work screen.

1.
2.
3.

TABLE H:

Accessory

Setup

Default Value/

Value to Enter Instructions/Defi nitions

Hopper Setup

# of Hoppers

1

# of hopper sensors connected to each module (4 sensors maximum). # of hop-

per data items for each listed module and the Hopp #’s value will automatically

populate if Auto Confi g is used to confi gure installed sensors.

Logic Level

Active Lo

Sets the active state to low signifying that an alarm is generated if the sensor’s

output is in a low state. Use this setting if the connected sensor outputs a low

condition when empty similar to the DICKEY-john hopper sensor.

Alarm Delay

5 sec

Controls the delay time between the detection of a high/low hopper alarm condi-

tion and the generation of the resulting alarm. The value is entered in seconds.

Channel

Assigns hopper sensor to channel.

RPM Setup

High Alarm

(fan speed)

3000 rpm

Sets the RPM value at which a high RPM warning error is generated.

Low Alarm

(fan speed)

1800 rpm

Sets the RPM value at which a low RPM warning error is generated.

High Alarm Delay

10 sec

Establishes the delay between the detection of a high RPM alarm condition and

the resulting alarm display. The value is entered in seconds.

Low Alarm Delay

10 sec

Establishes the delay between the detection of a low RPM alarm condition and

the resulting alarm display. The value is entered in seconds.

RPM Constant

3 pulses/rev

Number of pulses per sensor revolution.

RPM Filter

0

Filters the signal out of the RPM sensor.

Disable Control

on Low Alarm

Disabled

Allows for disabling of all control channels if the RPM value of the selected sen-

sor falls below the low alarm level setting.

STEP 10: Accessory Sensor Setup

Hopper Assignment

At the Main Work screen, press the Next Page button

.

Press the Module Confi guration button

to display the Module

Confi guration screen.
At the Module Confi guration screen, press the Hopper Assign button

.

Press Hopper Set button

.

Enter desired values using Table H as reference.

RPM Assignment

At the Module Confi guration screen, press the Accessory Assignment
button

.

Press the RPM Setup button

. NOTE: There must be at least 1

RPM sensor confi gured before the RPM Setup button appears on the
screen.
Enter desired values using Table H as reference.

1.
2.

3.

4.
5.

6.

7.

8.

STEP 11: Clutch Folding Module (CFM) Setup

The CFM is installed in the cab to control row clutches, wing fold, marker
tilt, and marker fold.

At the Main Work screen, press the Clutch CFG button to access the
Clutch Confi guration screen and verify that the correct # of clutches
are confi gured for the system.
The Clutch CFG button

only appears as a top level button

when a planter output module and clutch folding module are installed.

1.

2.

4

O U T P U T

1 - 6

# O F
R O W S

R O W
# ’ s

7 - 1 8

1 9 - 2 4

LEFT

CENTER
RIGHT

6

12

6

# of Clutches 3