Canola field update, Tools required, Update brushes – Great Plains YP4425A Material Rate User Manual

Page 38: Loosen meter, Tools required update brushes loosen meter

Advertising
background image

34

YP3025A, YP4025A and YP4425A

Table of Contents

Great Plains Manufacturing, Inc.

401-627B

Table of Contents

2014-05-13

Canola Field Update

If the inspection performed per “Pre-Requisites” on
page 29 indicates that y
our planter requires an update,
order one of the following kits per row:

Note: The kit includes one 817-991C canola seed disk.

Tools Required

• soft lint-free cloth and non-abrasive window cleaner

• 100% clear silicone sealant

• basic hand tools

• current parts manual (<multiple>) for parts ID

See Operator manual for details on steps 1-3, 5 and 19.

1.

Move planter to an area with adequate light, and a
clear surface for recovery of any dropped parts.
Perform a seed meter clean-out.

2.

For access to center rows, raise and fold planter.

3.

Remove rain covers and seed disks from all rows.

Perform remaining steps one row at a time, so that you
have unmodified and fully modified rows to compare to.
Starting with the right-most row may be the easiest. On
twin-row, locking up left rows of pairs may ease access.

Update Brushes

Refer to Figure 16
(which depicts the row with rain cover and seed disk removed,
and for clarity, the right gauge wheel and opener disc
removed. It is not necessary to remove the gauge wheel and
disc for this update)
4.

Rotate two brush holder snaps

securing the brush

holder for the long strip

and short strip

brushes, and the drop

brush. Remove and

discard

d

the old brushes. Save the brush holder.

Clean out brush slots in meter housing.

5.

Select one each new:

817-789C BRUSH, SEED DROP

891-118C BRUSH, STRIP, LONG

891-119C BRUSH, STRIP, SHORT

Install strip brushes in holder. Install holder and drop
brush in meter. Ensure strip brushes are seated low
in housing. Secure with snaps and bolts.

Loosen Meter

6.

Remove the clevis pin

that secures the seed

tube

to the opener shank. This pin is itself

secured by a cotter on the left side (not shown).
Save both pins.

Note: It is not necessary to disconnect the meter chain,

hoses or any sense line tubing.

7.

Remove and save two forward bolts

and the

forward rear bolt

securing meter mount to opener

shank. Loosen the aft rear bolt. Move meter mount to
left and rear.

Description

Part

Number

AIR PRO METER CANOLA FIELD KIT

403-684A

1

1

15

16

12

3

4

3

4

2

Figure 16

Canola Field Update: Brushes

36068

d. Older brushes do not reliably meter with the canola disk. Older brushes cannot be visually distinguished from newer brushes.

1

15

16

12

12
15
16

2

13

3

4

Advertising
This manual is related to the following products: