Umc coulter adjustments, Umc coulter depth adjustment – Great Plains YP825AR Operator Manual User Manual

Page 73

Advertising
background image

Great Plains Manufacturing, Inc.

Table of Contents

Index

Adjustments

69

2014-06-17

Table of Contents

Index

401-923M

UMC Coulter Adjustments

Note: Coulters are not factory-installed. Check alignment

and depth prior to first use.

UMC Coulter Depth Adjustment
The ideal operating depth for coulters is

1

4

inch (6 mm)

above opener depth. Although they may have originally
been set to this depth, coulter (and opener) blades wear
with time, and may need adjusting.

Adjusting the coulter depth is accomplished by
re-mounting the coulter blade in one of the three
mounting holes arranged in a staggered pattern in the
coulter bracket.

Refer to Figure 77 and Figure 78
Raise planter and install cylinder locks before working on
coulters. Row unit may be fully lowered or locked up. Do
not attempt to move blade when the current or new
position causes it to contact the ground during the
adjustment. Be careful around the front end of row units.
Row cleaner tines and coulter blades may be sharp.

To adjust coulter depth:

1.

Determine the present opener and coulter depths.

2.

Note which bracket hole the coulter is presently
using.

3.

Determine which new hole will position the coulter
closer to the

1

4

-inch-above depth. See the table

below.

4.

Remove the

5

8

-11 x 4 inch bolt, lock washer and

nut (

in Figure 77).

5.

Move the blade to the new position. Insert the bolt,
and tighten on the lock washer and nut.

6.

Re-adjust row cleaners, if installed.

If a worn coulter cannot be adjusted to satisfactory
operating depth, replace coulter.

Hole

Number

Depth of (new) coulter blade

relative to (new) opener blades

1

4

inch (6.4 mm) above opener

1

8

inch (3 mm) below opener

1

2

inch (13 mm) below opener

Figure 77

Short Unit-Mounted Coulter

34739

7

Figure 78

Coulter Blade Mounting Holes

34740

1

2

3

7

1

2

3

Advertising