2

Fan Sensor Kit

168-045M

10/09/2006

Installation

Prepare Both Sensors (all screen types)

Prepare New Sensor Assembly

Refer to Figure 1.

1.

Remove the nut (and lock washer) from the new sen-
sor

➀

.

2.

Insert the sensor through the new bracket

➁

from the

indented side.

3.

Loosely tighten the nut and washer - some adjust-
ment is required in a later step.

Cut Old Sensor Cable

Refer to Figure 2.

4.

Using wire cutters, cut the existing sensor cable

➂

near where it enters the fan screen.

An additional cut may be made later, but this first cut
provides ample reserve cable length.

Note: Cage screen assembly shown. Your implement

may have a flat screen.

Figure 1

Assemble New Sensor

25111

➀

➁

Figure 2

Cut Old Sensor Cable

25112

➂

Advertising