With the machine off the ground,

1. Pressurise the wings to unfold. As the

unfolding begins the pressure reading

on the gauge will drop. When the

wings have fully unfolded the pressure

reading will start to climb. Keep

pressurising the wings until the gauge

has stabilised at the pre-set pressure.

The standard factory setting is 15 bar.

2. If the system needs adjusting:- Partially

fold the wings & hold them in this

position. To adjust the pressure utilise

valve 3 (shown in Fig. 5.03). Unscrew

the adjusting screw until no resistance

can be felt (almost fully unscrewed

position). Unfold the wings fully as

before, checking the gauge reading.

Maintain hydraulic pressure unfolding

wings & adjust the screw whilst

pressurising.

Turning adjuster clockwise increases

pressure.

Turning adjuster anti-clockwise

decreases pressure.

Once the desired pressure is achieved lock

the valve. As a check, partially fold the wings,

stop, and then unfold again maintaining

pressure until the gauge stabilises at your