Option 1: air-ultrasonic – ADS Environmental Services Portable FlowShark Pulse QR 775006 A2 User Manual

Page 122

Advertising
background image

Parameter Settings

6-23

Submenu for level measurement

Additional programming may be required depending on the sensor
type selected. Selecting the wrong sensor will result in erroneous
measurements.

This menu allows you to define the parameters corresponding to depth measurement.
The start screen and the available parameters may vary based on the sensor type
selected.

First, scroll to the sensor type using the up and down arrow keys. Select or deselect
sensors using the ALT key. Choose from the following sensor types:

1

Air-ultrasonic depth sensor or mini air-ultrasonic depth sensor

2

Water-ultrasonic velocity/combination sensor

3

2-wire probe

4

Fixed value for full pipe applications or for testing

5

Pressure measurement cell integrated into water-ultrasonic
velocity sensor

Defining the sensor type

When using combination sensors featuring multiple depth
measurements (e.g., water-ultrasonic and pressure measurement
cell), select both depth measurements from the menu.

Option 1: Air-Ultrasonic

This option involves depth measurement using an air-ultrasonic depth sensor from the
top down. However, the water-ultrasonic velocity sensor may be used in conjunction
with this sensor. It requires an air-ultrasonic depth sensor or mini air-ultrasonic depth
sensor.

Advertising