6-48 ADS Portable FlowShark Pulse Manual

Signal Input/Output Menu (I/O)

This menu includes several submenus that enable you to access and to verify the
sensors as well as control signal inputs and outputs. It also displays various readings
and measurements, including current inputs and outputs, relay conditions, echo
profiles, and individual velocities. However, it does not enable you to modify signals
or settings, such as offsets, adjustments, or simulations. This menu primarily allows
you to access the parameter settings and diagnose errors.

I/O submenu

I/O: Independent Readings

This menu enables you to manage and examine the analog input values received
through ports 1 and 3 of the Portable FlowShark Pulse.

The display indicates the values available before (in mA/V) or after (calculated)
linearization of the analog inputs occurs.

Independent readings

Value in mA/V

This function is primarily used during the startup procedures for verifying the power
signals from external depth measurement units.

A 1 [mA] Input signal from socket 3

A 4 [mA] Input signal from multifunctional port 1. Indicates the input
current for the mA input.

Value in mA/V

Advertising