Setting the gun polarity for wire type, To attach the ground cable with clamp – Chicago Electric MIG 200 93804 User Manual

Page 16

Advertising
background image

For technical questions, please call 1-800-444-3353;

Troubleshooting section at end of manual.

Page 16

SKU 93804

SETTING THE GUN POLARITY FOR WIRE TYPE

1.

Set for Electrode Positive (DCEP) for gas welding with solid-core wire. Red
Electrode Cable (C) to Positive Terminal (A); Black Ground Cable (D) to Negative
Terminal (B). SHOWN IN ILLUSTRATION, INITIAL SETUP. (See Figure K.)

2.

Set for Electrode Negative (DCEN) for gas-less flux
core wire. Red Electrode Cable (C) to Negative
Terminal (B); Black Ground Cable (D) to Positive
Terminal (A). (See Figure K.)

3.

When connecting to the weld output terminals, do
not place anything between the welding Cable
Terminals (A and B) and their copper connections.
(See Figure K.)

4.

Always read and follow wire manufacturer’s
recommended polarity.

5.

A. Positive (+) Output Terminal
B. Negative (–) Output Terminal
C. Red Cable - Electrode
D. Black Cable - Ground

TO ATTACH THE GROUND CABLE WITH CLAMP

1.

Insert the bare end of the Ground Cable (11D) upward through the hole located at
the rear of the Ground Clamp (11D). Then secure the bare end of the Ground Cable
to the Ground Clamp, using the Bolt, Lock Washer, and Nut provided.
(See Figure L.)

2.

Insert the Connecting Plug of the Ground Cable (11D) into the Terminal Ground
(10D) and twist the Connecting Plug to lock it in place. (See Figure L.)

FIGURE L

WELDER

(SIDE VIEW)

TORCH CABLE

CONNECTING

PLUG

TERMINAL GROUND (10D)

GROUND CABLE WITH CLAMP

(11D)

BOLT, LOCK WASHER, NUT

FIGURE K