Bio-Rad Quantity One 1-D Analysis Software User Manual
Page 208
Chapter 9. Differential Displays and VNTRs
9-5
Fig. 9-3. Diagram of components of a DNA fragment.
In the Repeated Unit Size field, enter the size in base pairs of the repeated element 
(e.g., if you are working with (CA) repeats, enter “2”).
Testing for Ambiguity
The number of repeats calculated by the software may not be a whole number, due to 
the limitations of exact band size determination. Since the number of times an 
element is repeated must be a whole number, the calculated value is rounded to the 
nearest whole number.
In the dialog box, you have the option to “flag” those numbers
Select Yes after Test for ambiguity? to flag values that deviate from the nearest 
whole number by a certain fraction. These values may warrant further review. In the 
Ambiguous if rounded > field, specify how much the calculated value must deviate 
from the nearest whole number for it to be flagged.
Finally, specify how to identify the ambiguous values using the Flag with * button or 
the Leave Blank button.
When you have entered all the information in the dialog box, click on the Done 
button. The number of tandem repeats will be displayed next to the bands. (Note that 
if no standards have been defined on the gel, no numbers will be displayed.)
If the numbers have been concealed (e.g., by the Hide Overlays command), you can 
redisplay them by selecting VNTR Display.
PCR Primer
Sequence between primer and VNTR
VNTR repeat unit