Outputs / other settings – Carlo Gavazzi WM3-96 User Manual

Page 28

Advertising
background image

29

To conclude the RESET procedure, press

; to go back to

the TARIFF SELECTION menu, press

.

The reset procedure allows the user to choose
among the following different choices:
ALL: reset of all the energy meters (imported/
exported energies);
TOTAL + : reset of the imported energy me-
ters (+kWh, +kvarh);

TOTAL - : reset of the exported energy meters (-kWh, -kvarh);
PARTIAL + : reset of the partial imported energy meters
(+kWh, +kvarh);
PARTIAL - : reset of the partial exported energy meters
(-kWh, -kvarh).

HARMONIC ANALYSIS

This function enables the display of
the windows relating to the harmonic
analysis.
Press

to enter the menu; then,

use the

and

keys to select

the phase where you want to enable
the harmonic analysis. The

key

allows the user to enable (ON) or
disable (OFF) the displaying (the
function is cyclical: ON-OFF-ON).
To go back to the main menu, press

.

Outputs / Other settings

Multi tariff

27

37

Alarm parameters

33

Advertising