Cooper Instruments & Systems DFI 250X Digital Weight Indicator User Manual
Page 4

CF 146
2
V- Rev. 1.0 - 003R-620-100
Drive Outputs
2 isolated transistor drive outputs (300mA total at 50VDC)
Battery Backed Clock Calendar
Battery life 10 years minimum
4.0 WARNINGS
4.1 General
•
Indicator not to be subject to shock, excessive vibration or extremes of temperature (before or after installation).
•
Inputs are protected against electrical interference, but excessive levels of electro-magnetic radiation and RFI
may affect the accuracy and stability.
•
For full EMC or for RFI immunity, termination of cable shields and correct earthing of the instrument is
essential.
•
Indicator and load cell cable are sensitive to excessive electrical noise. Install well away from any power or
switching circuits.
4.2 Configuration Issues
•
Configuration and calibration can be performed from the front panel, using digital setup. When Full Setup is
used, all menu items are accessible and care must be taken to ensure no accidental changes are made to
calibration and trade settings.
•
Enter a passcode to prevent unauthorized or accidental tampering. If the passcode is lost, GSE Scale Systems
should be contacted for further advice.
5.0 INSTALLATION
The following steps are required to set up the indicator.
•
Inspect indicator to ensure good condition.
•
Use connection diagrams to wire up load cell, power and auxiliary cables as required.
•
Use the drill hole template provided for hole locations.
•
Connect Power to indicator and press <POWER> key to turn the instrument On.
•
Refer to the Instrument Setup section page 15 for information on configuring and calibrating the instrument.
•
To turn instrument Off press and hold <POWER> key for three seconds (until display blanks).
5.1 Electrical Safety
•
For your protection all electrical hardware must be rated for environmental conditions of use.
•
Pluggable equipment must be installed near an easily accessible power socket outlet.
•
To avoid the possibility of electric shock or damage to the instrument, always switch off or isolate the
instrument from the power supply before maintenance is carried out.
5.2 Panel Mount Template
Use the panel mount template for drill hole locations. The template indicates positions for the two 4mm mounting
screws through the panel. Also displayed on the template is the position of the rectangular hole that should be cut
to allow for the connection of cables. The drilling template supplied with the indicator allows for front or rear
machining of the panel.
5.3 Special Function Key
•
The Special Function Key on the instrument ships as a blank key.
•
If any of the special functions are to be used on the indicator it is important that the matching function key
overlay sticker (supplied) is applied to the keypad.
•
Ensure keypad is clean and dry before affixing sticker.