85

t

D

Measuring Preset White Balance

If no operations are performed while the displays are flashing, direct measurement mode
will end when the exposure meters turn off. The auto meter-off delay can be changed using
the Auto off timers option in the setup menu (

0 130). The default setting is eight seconds.

D

Preset White Balance

The camera can store only one value for preset white balance at a time; the existing value will
be replaced when a new value is measured. Note that exposure is automatically increased
by 1 EV when measuring white balance; when shooting in mode M, adjust exposure so that
the exposure indicator shows ±0 (

0 71).

A

Other Methods for Measuring Preset White Balance

To enter preset measurement mode (see above) after selecting preset white balance in the
information display (

0 80), press J for a few seconds. If white balance has been assigned to

the Fn (

E) button (0 134) and preset white balance selected by pressing the Fn (E) button

and rotating the command dial, the camera will also enter preset measurement mode if the
Fn

(

E) button is pressed for a few seconds.

A

Studio Settings

In studio settings, a standard gray panel can be used as a reference object when measuring
preset white balance.

Advertising