Maytag GEMINI User Manual

Page 18

Advertising
background image

©2000 Maytag Appliances Sales Company

16010107

Section 3. Component Description

3-8

HI-LIMIT THERMOSTAT

The HI-Limit Thermostat is mounted to
range main back. The purpose of this
thermostat is to break line voltage to oven
control in case of a runaway temperature.
Range may be removed from cabinetry for
rear serviceability.

Thermostat Replacement

1. Disconnect the appliance from power

source before servicing.

2. Slide unit out of installation.

3. Remove screws securing main back

shield and remove shield.

4. Remove two (2) screws securing

thermostat to range main back.

5. Disconnect wiring.

6. Replace in reverse order.

OVEN DOOR(S)

Do not place excessive weight on an open
oven door or stand on an opened door as, in
some cases, it could cause the range to tip
over, breakage of the door, or serious injury.

Both the upper and lower oven doors are
removable.

To Remove Lift-Off Door:

Open door to stop position. In stop position
door is open approximately 4”. Grasp door
as illustrated. Lift up evenly until door clears
the hinge arms.

DO NOT USE DOOR HANDLE TO LIFT
DOOR.

To Replace:

1. Grasp door at each side.

2. Align slots in the door with the hinge

arms on the range.

3. Slide the door down onto the hinge

arms until the door is completely

Contacts normally closed

Close Temperature - 250 ± 11ºF

Open Temperature - 300 ± 8ºF

CAUTIONS:

• Do not attempt to open or close door

or operate oven until door is properly
replaced.

• Hinge arms are spring mounted and

will slam shut if accidentally hit.
Never place hand or fingers between
the hinges and the front oven frame.
You could be injured if hinge snaps
back.

Advertising