Section 4. Electrical

4-3

TEM PERATURE

RESISTANCE

100 Degrees F

1143 Ohm s

200 Degrees F

1350 Ohm s

300 Degrees F

1553 Ohm s

350 Degrees F

1654 Ohm s

400 Degrees F

1753 Ohm s

500 Degrees F

1949 Ohm s

600 Degrees F

2142 Ohm s

700 Degrees F

2331 Ohm s

800 Degrees F

2516 Ohm s

900 Degrees F

2697 Ohm s

1000 Degrees F

2874 Ohm s

HOT SURFACE LIGHTS

Each element has a HOT SURFACE indicator
light. A light will be illuminated when the
matching cooking area is hot. It will remain
on, even after the control is turned off, until
the area has cooled. They are located at the
front center of the cooktop.

SURFACE INDICATOR LIGHTS

There is an indicator light by each pair of
control knobs. When one or both of the
surface control knobs is turned on, the light
will turn on. The light will turn off when the
surface element(s) is turned off.

To check oven sensor:

1. Access sensor wires as outlined under

sensor removal.

2. Set meter to RX1000 Scale.

3. Check for the following:

Advertising