Edge Lighting 300W/12V Electronic Remote Transformer User Manual
Page 3
C
3
8: Install a conduit from the transformer to the electrical box.
9: For the best performance, use the "Low Voltage Wire Size
Chart" below to select the wire size.
NOTE: Using a smaller wire size other than specified will result in
a increase in voltage drop and will reduce the lamp intensity.
NOTE: The THHN wire sizes specified in "Low Voltage Wire Size
Chart" are for 3% or less drop in voltage based on 300 watt
loads. Lengths are the distance from the remote transformer to
the system power feed connector, or power feed canopy.
10: Install the THHN low voltage wires from the transformer to
the electrical box where the power feed will be installed.
11: Connect one blue transformer wire to each low voltage wire
with a wire nut.
CONDUIT
8
LOW VOLTAGE WIRE SIZE CHART
TRANSFORMER
WATTAGE
WIRE SIZE
FOR 5 FT
WIRE SIZE
FOR 6-15 FT
WIRE SIZE
FOR 16-20 FT
WIRE SIZE
FOR 21-40 FT
300 WATT
#10 GA
#6 GA
#4 GA
#1 GA
11
11
10
ELECTRICAL
BOX