INSTALLATION INSTRUCTIONS

Gas connection

All connections must be wrench-tightened

Flare

Union

Flare

Union

GAS FLOW

Manual

Shutoff

Valve

Closed

Open

Flexible

Connector

Inlet Pipe on

Back of Dryer

e

l

p

p

i

N

Shutoff Valve -

Open position

to dr

yer

from gas supply

1 Remove the shipping cap from gas pipe at the rear

of the dryer.

4 Check for gas system leaks with a manometer. If a

manometer is not available, test all connections by

brushing on a soapy water solution.

3 Open the shutoff valve in the gas supply line to

allow gas to fl ow through the pipe. Wait a few

minutes for gas to move through the gas line.

2 Connect a 1/2 inch (1.27 cm) I.D. semi-rigid or

approved pipe from gas supply line to the 3/8 inch

(0.96 cm) pipe located on the back of the dryer.

Use a 1/2 inch to 3/8 inch (1.27 cm to 0.96 cm)

reducer for the connection. Apply an approved

thread sealer that is resistant to the corrosive

action of liquefi ed gases on all pipe connections.

WARNING

EXPLOSION HAZARD

NEVER test for gas leaks with an open fl ame.

IMPORTANT

DO NOT connect the dryer to L.P. gas service without

converting the gas valve. An L.P. conversion kit must

be installed by a qualifi ed gas technician.

IMPORTANT

The supply line must be equipped with an approved

manual shutoff valve. This valve should be located in

the same room as the dryer and should be in a location

that allows ease of opening and closing. Do not block

access to the gas shutoff valve.