INSTALLATION REQUIREMENTS

WARNING

EXPLOSION HAZARD

Uncoated copper tubing will corrode when subjected

to natural gas, causing gas leaks. Use ONLY black iron,

stainless steel, or plastic-coated brass piping for gas

supply.

Gas supply requirements

Electrical requirements for gas dryer

CIRCUIT - Individual, properly polarized and grounded

15 amp. branch circuit fused with 15 amp. time delay

fuse or circuit breaker.

POWER SUPPLY - 2-wire, with ground, 120 volt, single

phase, 60 Hz, Alternating Current.

POWER SUPPLY CORD - The dryer is equipped with a 120

volt 3-wire power cord.

GROUNDING CONNECTION - See “Grounding

requirements” in Electrical Installation section.

Grounding type

Grounding type
wa

wall receptacl

ll receptacle

Po

Power cord with

wer cord with

3-prong

3-prong gr

grounded plug

ounded plug

Do not,

Do not, under

under

an

any cir

y circumstances,

cumstances,

cut,

cut, remo

remove

ve,

or b

or bypass th

ypass the

gr

grounding pr

ounding prong.

ong.

1 Installation MUST conform with local codes, or in

the absence of local codes, with the National Fuel

Gas Code, ANSI Z223.1 (latest edition).

2 The gas supply line should be 1/2 inch (1.27 cm)

pipe.

3 If codes allow, fl exible metal tubing may be used

to connect your dryer to the gas supply line. The

tubing MUST be constructed of stainless steel or

plastic-coated brass.

4 The gas supply line MUST have an individual

shutoff valve installed in accordance with the

B149.1, Natural Gas and Propane Installation Code.

5 A 1/8 inch (0.32 cm) N.P.T. plugged tapping,

accessible for test gauge connection, MUST be

installed immediately upstream of the gas supply

connection to the dryer.

6 The dryer MUST be disconnected from the gas

supply piping system during any pressure testing

of the gas supply piping system at test pressures in

excess of 1/2 psig (3.45 kPa).

7 The dryer MUST be isolated from the gas supply

piping system during any pressure testing of the

gas supply piping system at test pressures equal to

or less than 1/2 psig (3.45 kPa).

8 Connections for the gas supply must comply with

the Standard for Connectors for Gas Appliances,

ANSI Z21.24.