INSTALLATION INSTRUCTIONS

Electrical connection (non-Canada) - 3 wire cord

3-wire receptacle

(NEMA type 10-30R)

Internal ground

Internal ground

(GREEN screw)

(GREEN screw)

Install

Install

UL-approved

UL-approved

strain relief here

strain relief here

Terminal screw

Terminal screw

recovery slot

recovery slot

Line 1

Line 1

(BRASS terminal)

(BRASS terminal)

Neutral

Neutral

(SILVER terminal)

(SILVER terminal)

Line 2

Line 2

(BRASS terminal)

(BRASS terminal)

Access cover

Access cover

screw

screw

Terminal

Terminal

block

block

Neutral

Neutral

(center wire)

(center wire)

30 AMP

30 AMP

NEMA 10-30

NEMA 10-30

DO NOT remove

DO NOT remove

internal ground in

internal ground in

a 3-wire system!!

a 3-wire system!!

Neutral

Neutral

terminal

terminal

1 Turn off power supply to outlet.
2 Remove the screw securing the terminal block

access cover in the lower corner on the back of the

dryer.

3 Install a UL-approved strain relief according to the

power cord/strain relief manufacturer’s instructions

in the power cord entry hole below the access

panel. At this time, the strain relief should be

loosely in place.

4 Thread an UNPLUGGED, UL-approved, 30 amp.

power cord, NEMA 10-30 type SRDT, through the

strain relief.

5 Attach the power cord neutral (center wire)

conductor to the SILVER colored center terminal on

the terminal block. Tighten the screw securely.

6 Attach the remaining two power cord outer

conductors to the outer, BRASS colored terminals

on the terminal block. Tighten both screws

securely.

7 Follow manufacturer’s guidelines for fi rmly securing

the strain relief and power cord.

8 Reinstall the terminal block cover.

WARNING

ELECTRICAL SHOCK HAZARD

Failure to disconnect power source before servicing

could result in personal injury or even death.

WARNING

ELECTRICAL SHOCK HAZARD

Do not make a sharp bend or crimp wiring/conductor

at connections.

IMPORTANT

If moving dryer from a 4-wire system and installing it

in a 3-wire system, move the internal ground from the

center terminal back to the GREEN screw next to the

terminal block.

NOTE

If a terminal screw falls during cord installation, it can

be retrieved in the terminal screw recovery slot below

the access panel.