Routing cables – Dell PowerEdge 1750 User Manual

Page 20

Advertising
background image

1-14

Ra c k I n s t a l l a t i o n G u i d e

www

.dell.com | support.dell.com

7

Route the status-indicator end of the cable assembly through the cable-management
arm, and install the indicator in its slot at the back end of the cable-management arm
(see Figure 1-9).

8

Connect the power cords to their receptacles on the back panel.

NOTICE: Although the strain-relief can accommodate power cords with a bend radius

of up to 19 mm (0.75 inch), the system manufacturer recommends that you only use
the power cords provided with the system.

9

Install a tie-wrap through the slot on the strain-relief tab (see Figure 1-10).

10

Bend the power cords back beside the power receptacle housing, forming a tight loop,
and install the strain-relief tie-wrap loosely around the looped power cords (see
Figure 1-10).

F i g u r e 1 - 1 0 .

I n s t a l l i n g t h e P o w e r C o r d S t r a i n R e l i e f

Routing Cables

1

Attach the I/O cable connectors to their respective connectors on the system back.

For details on cable connections, see your system’s Installation and Troubleshooting
Guide and the User’s Guide.

power cord strain-relief tab and tie wrap

power cord plug

power receptacle housing

5X860eb0.fm Page 14 Monday, October 21, 2002 11:49 AM