Dell POWEREDGE M1000E User Manual

Page 12

Advertising
background image

12 of 192

Dell M8428-k Getting Started Guide

MHWKY A01

Connecting the converged network switch to the fabric

1.

The switch module is delivered with FC 8G SFP transceivers installed in the four fibre channel ports.

2.

If you need to connect the Ethernet ports, install 10GE SFP+ transceivers or twin-ax cables in the external ports
as required. Be sure you have all the necessary SFP transceivers as well as either optical or active twin-ax
copper cables.

a.

If necessary, remove the end caps from the SFP.

b.

Orient the transceiver correctly and insert it into a port until it is firmly seated and the latching mechanism
clicks.

For instructions specific to the type of transceiver, refer to the transceiver manufacturer’s documentation.

c.

Repeat substeps a, b, and c for the remaining ports, as required.

NOTE

Use only Dell-approved SFPs or active twin-ax copper cables in the appropriate external optical ports of this
module. The FC 8G SFP transceivers included in the 4 Fibre Channel ports (25, 26, 27, and 0) of the switch
module are not compatible with the Ethernet ports (17 through 24). The Ethernet ports should be populated
with Dell-Approved 10GE SFP+ transceivers, or active twin-ax copper cables (not included).

ATTENTION

A cable should not be bent to a radius less than 5.08 cm (2 inches) under full tensile load and 3.048 cm (1.2
inches) with no tensile load. Tie wraps are not recommended for optical cables because they are easily over
tightened.

d.

Orient a cable connector so that the key (the ridge on one side of connector) aligns with the slot in the
transceiver

e.

Insert the cable into the transceiver until the latching mechanism clicks. For instructions specific to cable
type, refer to the cable manufacturer's documentation.

f.

Repeat for the remaining transceivers as required.

3.

Connect the cables to the transceivers.

The transceivers are keyed to ensure correct orientation. If a transceiver does not install easily, ensure that it is
correctly oriented and that the end caps have been removed.

4.

Check the LEDs to verify that all components are functional.

For information about LED patterns, see the “Operating the converged network switch” chapter in the Dell
M8428-k Hardware Reference Manual.

NOTE

Commands below are run from the FOS CLI, as needed exit the CEE CLI, or login to the Switch with a terminal
emulator session and gain access the FOS prompt

M8428-k:Admin>

5.

Once the switch module FC port is connected to an FC SAN switch, the ports need to be enabled. From the
switch module FOS CLI enter the following command for the ports being used (this can also be enabled from the
switch GUI):

M8428-k:admin> portcfgpersistentenable <port#>, where the port# is 25, 26, 27 or 0.

6.

Verify the correct operation of the converged network switch by typing the switchShow command from the
workstation. This command provides information about the switch module and port status.

Advertising