1.

Click the I/O Module Overview in the navigation panel of the CMC menu.

2.

Open the CMC application’s Setup tab.

FIGURE 4

CMC Setup Tab

3.

Enter the new information in the IP Address for the correct I/O slot, Subnet Mask, and Gateway fields, or enable
DHCP, as appropriate and click Apply.

ATTENTION

In order to see the applied settings click the “Refresh” icon.

NOTE

TRefer to the documentation for the Dell Chassis Management Controller (CMC) for additional GUI detail.

Using the CMC CLI to set the IP address

Use the following steps to connect and modify the converged network switch IP address through the CMC CLI.

1.

Establish a Telnet session to the CMC CLI.

At the CMC login prompt, enter the CMC username and password.

2.

At the command prompt, type the setniccfg command with the correct IP information as shown in the following
example:

$ racadm setniccfg -m switch-x -s 10.32.53.47 255.255.240.0 10.32.48.1
Static IP address modified succesfully

3.

Substitute the correct value for switch-x where x is the bay where the switch module is installed. For example,
switch-x can be: