11

!!*** Error: Remote

Access Controller

initialization

failure *** RAC

virtual USB devices

may not be

available...

Remote Access Controller
initialization failure

Ensure that the Remote
Access Controller is
properly installed. See
“Installing a RAC Card”
in the Hardware Owner’s
Manual.

Invalid PCIe card

found in the

Internal_Storage

slot!

The system halted because
an invalid PCIe expansion
card is installed in
the dedicated storage
controller slot.

Remove the PCIe
expansion card and install
the internal SAS controller
in the dedicated slot.

No boot device

available

Faulty or missing optical
drive subsystem, hard
drive, or hard-drive
subsystem, or no bootable
USB key installed.

Use a bootable USB key,
CD, or hard drive. See
“Using the System Setup
Program” in the Hardware
Owner’s Manual for
information on setting
the order of boot devices.

PCI BIOS failed

to install

PCIe device BIOS (Option
ROM) checksum failure
detected during shadowing.

Cables to expansion card(s)
loose; faulty or improperly
installed expansion card(s).

Reseat the expansion
card(s). Ensure that all
appropriate cables are
securely connected to
the expansion card(s).
If the problem persists, see
“Troubleshooting System
Expansion Cards” in the
Hardware Owner’s Manual.

PCIe Degraded Link

Width Error:

Embedded device

Expected Link

Width is n

Actual Link

Width is n

Faulty system board
or riser board.

See see “Getting Help”
in the Hardware Owner’s
Manual.

Table 1-1.

System Messages (continued)

Message

Causes

Corrective Actions