Dell POWEREDGE 2950 User Manual

Page 18

Advertising
background image

18

Information Update

E1914

DRAC5 Conn2

Cbl

DRAC 5 cable is missing
or disconnected.

Reconnect the cable.
See “Installing a RAC
Card” in the Hardware
Owner’s Manual.

E1B01

USB#

Overcurrent

Device plugged in the
specified USB port caused
an overcurrent condition.

Reseat the device cable.
If the problem persists,
replace or remove the
device.

E2110

MBE

DIMM # & #

One of the two indicated
DIMMs has had a
memory multi-bit error
(MBE).

See “Troubleshooting
System Memory” in the
Hardware Owner’s
Manual.

E2111

SBE Log

Disable

DIMM #

The system BIOS has
disabled memory single-
bit error (SBE) logging,
and does not resume
logging further SBEs until
the system is restarted.
“#” represents the DIMM
implicated by the BIOS.

See “Troubleshooting
System Memory”
in the Hardware
Owner’s Manual.

E2112

Mem Spare

DIMM #

The system BIOS has
spared the memory
because it has determined
that the memory had
too many errors. “# & #”
represents the DIMM pair
implicated by the BIOS.

See “Troubleshooting
System Memory”
in the Hardware
Owner’s Manual.

I1915

Video Off

(LCD lights with
a blue or amber
background.)

The video has been
turned off by the RAC
remote user.

Information only.

I1916

Video Off

in ##

(LCD lights with
a blue or amber
background.)

The video was turned off
in xx seconds by the RAC
remote user.

Information only.

Table 1-2.

LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions

Advertising