13

PCIe Training

Error: Slot n

Faulty or improperly
installed PCIe card in
the specified slot.

Reseat the PCIe card in the
specified slot number. See
“Expansion Cards” in the
Hardware Owner’s Manual.
If the problem persists, see
“Getting Help” in the
Hardware Owner’s Manual.

Remote Access

Controller cable

error or incorrect

card in the RAC

slot.

RAC cables not connected,
or RAC card installed in
wrong expansion slot.

Check that the RAC cables
are connected, and that the
RAC card is installed in the
correct expansion slot. See
“Installing a RAC Card” in
the Hardware Owner’s
Manual.

NOTE:

All TPM information messages appear after the BMC option ROM has been

loaded during POST.

TPM configuration

operation honored.

System now resets.

Information only.

TPM Failure

A Trusted Platform Module
(TPM) function has failed.

See “Getting Help” in the
Hardware Owner’s Manual.

TPM operation is

pending. Press I to

Ignore or M to

Modify to allow

this change and

reset the system.

WARNING: Modifying

could prevent

security.

Configuration change has
been requested.

Press I to continue system
boot. Press M to modify
the TPM setting and
restart.

Warning: Following

faulty DIMMs are

disabled:

DIMM

n

1

n

2

Total memory size

is reduced.

Faulty or improperly
seated memory module(s).
DIMMs are disabled in
pairs, as indicated by the n

1

and n

2

. Check both

DIMMs for a possible fault.

See “Troubleshooting
System Memory” in the
Hardware Owner’s Manual.

Table 1-1.

System Messages (continued)

Message

Causes

Corrective Actions