Wire creates a bird’s nest during operation, Wire feeds, but arc does not ignite – Chicago Electric 90 AMP FLUX WIRE WELDER 68887 User Manual

Page 23

Advertising
background image

Page 23

For technical questions, please call 1-800-444-3353.

Item 68887

Troubleshooting

IMPORTANT!

Be CERTAIN to shut off the Welder, disconnect it from power, and discharge the Gun to ground

before adjusting, cleaning, or repairing the unit.

Wire Feed Motor Runs But Wire Does Not Feed Properly

POSSIBLE CAUSES AND SOLUTIONS

1.

Insufficient wire feed tension:

Increase wire feed tension properly – follow number 16 on page 11.

2.

Incorrect wire feed roll size:

Replace with the proper wire feed roll – follow the Wire Spool Installation instructions, starting on page 8.

Flip over wire feed roll if necessary.

3.

Damaged Gun, cable, or liner assembly:

Have a qualified technician inspect these parts and replace as necessary.

Wire Creates A Bird’s Nest During Operation

POSSIBLE CAUSES AND SOLUTIONS

1.

Excess wire feed tension:

Adjust wire feed tension properly – follow number 16 on page 11.

2.

Incorrect contact tip size:

Replace with the proper tip for the wire.

3.

Gun end not inserted into drive housing properly:

Loosen gun securing bolt and push gun end into housing just enough

so that it does not touch wire feed mechanism.

4.

Damaged liner:

Have a qualified technician inspect and repair/replace as necessary.

Wire Feeds, But Arc Does Not Ignite

POSSIBLE CAUSES AND SOLUTIONS

1.

Improper ground connection:

Make certain that the workpiece is contacted properly by the Ground Clamp and that the

workpiece is properly cleaned near the ground clamp and the welding location.

2.

Improperly sized or excessively worn Contact Tip:

Verify that Contact Tip is the proper size for the wire. Check that the hole in the tip

is not deformed or enlarged. Also, check that the tip is not dirty; this would prevent a

good connection. If needed, replace Contact Tip with proper size and type.

Power Switch Lights,

But Welder Does Not Function When Switched On

POSSIBLE CAUSES AND SOLUTIONS

1.

Tripped thermal protection device:

Shut the Welder’s switch to off and allow it to cool for at least 20 minutes.

Reduce duration or frequency of welding periods to help reduce wear on the Welder.

Refer to Duty Cycle section on page 14.

2.

Faulty or improperly connected Trigger:

Qualified technician must check and secure/replace Trigger.

SAFETY

MAINTENANCE

BASIC WELDING

WELDING TIPS

SETUP

Advertising