Wire spool installation – Chicago Electric 90 AMP FLUX WIRE WELDER 68887 User Manual
Page 8
Page 8
For technical questions, please call 1-800-444-3353.
Item 68887
1. Turn the Welder to OFF and unplug
it before proceeding.
2. Press in the pin at the top center of
the control panel and open the Cover.
3. Remove the Knob, Spring and the Top Plate.
If replacing a Spool, remove the old Spool
and all remaining wire from the liners.
4. Place the new flux-core Wire Spool
over the Spool Spindle.
To prevent wire feed problems, set the Spool
so that it will unwind counterclockwise .
5. Replace the Top Plate (turned as shown in
illustration), the Spring and the Knob.
ON
MIN
OFF
MAX
WIRE FEED SPEED
GUN
GROUND
120V~
60Hz
20A
90 AMP FLUX WIRE WELDER
ITEM 68887
Specifications
Wire
0.030" – 0.035" Flux-Core
Capacity 18 Ga. – 3/16" Steel Plate
Weldable
Materials
Mild, Low Alloy Steel
(Not for Aluminum or Stainless Steel)
Wire
Spool
Cover
Wire Spool
Spring
Top Plate
Knob
Spindle
.030″
wire must
unwind in this
direction
Wire Spool Installation
SAFETY
MAINTENANCE
BASIC WELDING
WELDING TIPS
SETUP