1. Turn the Welder to OFF and unplug

it before proceeding.

2. Press in the pin at the top center of

the control panel and open the Cover.

3. Remove the Knob, Spring and the Top Plate.

If replacing a Spool, remove the old Spool

and all remaining wire from the liners.

4. Place the new flux-core Wire Spool

over the Spool Spindle.

To prevent wire feed problems, set the Spool

so that it will unwind counterclockwise .

5. Replace the Top Plate (turned as shown in

illustration), the Spring and the Knob.

ON

MIN

OFF

MAX

WIRE FEED SPEED

GUN

GROUND

120V~

60Hz

20A

90 AMP FLUX WIRE WELDER

ITEM 68887

Specifications

Wire

0.030" – 0.035" Flux-Core

Capacity 18 Ga. – 3/16" Steel Plate

Weldable 

Materials

Mild, Low Alloy Steel 

(Not for Aluminum or Stainless Steel)

Wire

Spool

Cover

Wire Spool

Spring

Top Plate

Knob

Spindle

.030″

wire must

unwind in this

direction