Ac switching characteristics – Cypress CY14B101P User Manual
Page 24

PRELIMINARY
CY14B101P
Document #: 001-44109 Rev. *B
Page 24 of 32
Table 12. RTC Characteristics
Parameters
Description
Test Conditions
Min
Typ
Max
Units
I
BAK
[7]
RTC Backup Current
Room Temperature (25
o
C)
300
nA
Hot Temperature (85
o
C)
450
nA
V
RTCbat
RTC Battery Pin Voltage
1.8
3.0
3.3
V
V
RTCcap
RTC Capacitor Pin Voltage
1.5
3.0
3.6
V
t
OCS
RTC Oscillator Time to Start
1
2
sec
AC Switching Characteristics
Cypress
Parameter
Alt. Parameter
Description
40 MHz
25 MHz
(RDRTC Instruction)
Unit
Min
Max
Min
Max
f
SCK
f
SCK
Clock Frequency, SCK
40
25
MHz
t
CL
t
WL
Clock Pulse Width LOW
11
18
ns
t
CH
t
WH
Clock Pulse Width HIGH
11
18
ns
t
CS
t
CE
CS HIGH Time
20
20
ns
t
CSS
t
CES
CS Setup Time
10
10
ns
t
CSH
t
CEH
CS Hold Time
10
10
ns
t
SD
t
SU
Data In Setup Time
5
5
ns
t
HD
t
H
Data In Hold Time
5
5
ns
t
HH
t
HD
HOLD Hold Time
5
5
ns
t
SH
t
CD
HOLD Setup Time
5
5
ns
t
CO
t
V
Output Valid
9
15
ns
t
HHZ
t
HZ
HOLD to Output HIGH Z
15
15
ns
tH
LZ
t
LZ
HOLD to Output LOW Z
15
15
ns
t
OH
t
HO
Output Hold Time
0
0
ns
t
HZCS
t
DIS
Output Disable Time
25
25
ns
Notes
7. Current drawn from either V
RTCcap
or V
RTCbat
when V
CC
< V
SWITCH.