Software controlled store/recall cycles – Cypress CY14B101P User Manual
Page 27
Advertising

PRELIMINARY
CY14B101P
Document #: 001-44109 Rev. *B
Page 27 of 32
Software Controlled STORE/RECALL Cycles
Parameter
Description
CY14B101P
Unit
Min
Max
t
RECALL
RECALL Duration
200
µs
t
SS
Soft Sequence Processing Time
100
µs
Figure 28. Software STORE Cycle
Figure 29. Software RECALL Cycle
0 0
1 1
1 1
0
0
CS
SCK
SI
RWI
Hi-Z
0 1 2 3
4 5
6 7
RDY
tSTORE
0 1
1 0
0 0
0
0
CS
SCK
SI
0 1
2 3
4 5
6 7
RWI
Hi-Z
RDY
tRECALL
Notes
12. This is the amount of time it takes to take action on a soft sequence command. Vcc power must remain HIGH to effectively register command.
13. Commands such as STORE and RECALL lock out IO until operation is complete which further increases this time. See the specific command.
Advertising