Exit, Racadm chassisaction -m switch-<n> powercycle, Connect switch-<n – Dell POWEREDGE M1000E User Manual

Page 18: Fw updated successfully

Advertising
background image

Software User’s Manual

Rev 1.00

18

Note:

The update process takes a few minutes.

At the end of this process, the following message will be displayed at the prompt:

# Received update image successfully. Changes will take effect after
next reboot.
#

Step 6.

Exit the 10GbE PTM CLI to the CMC command line. Run:

# exit

Step 7.

Power cycle the 10GbE PTM for the firmware to take effect. From the CMC command line type
the following command:

$ racadm chassisaction -m switch-<n> powercycle

Step 8.

Wait for 20 seconds, and then connect to the 10GbE PTM. Run:

$ connect switch-<n>

You will be able to view the progress of the SW update.

Step 9.

At the end of a successful SW update process, the following message will be displayed:

FW updated successfully!
Welcome to the Dell 10GbE PTM Management Console firmware X.X.XXX-<date
stamp>
#

Advertising