Exit, Racadm chassisaction -m switch-<n> powercycle, Connect switch-<n – Dell POWEREDGE M1000E User Manual
Page 18: Fw updated successfully
Software User’s Manual
Rev 1.00
18
Note:
The update process takes a few minutes.
At the end of this process, the following message will be displayed at the prompt:
# Received update image successfully. Changes will take effect after
next reboot.
#
Step 6.
Exit the 10GbE PTM CLI to the CMC command line. Run:
# exit
Step 7.
Power cycle the 10GbE PTM for the firmware to take effect. From the CMC command line type
the following command:
$ racadm chassisaction -m switch-<n> powercycle
Step 8.
Wait for 20 seconds, and then connect to the 10GbE PTM. Run:
$ connect switch-<n>
You will be able to view the progress of the SW update.
Step 9.
At the end of a successful SW update process, the following message will be displayed:
FW updated successfully!
Welcome to the Dell 10GbE PTM Management Console firmware X.X.XXX-<date
stamp>
#