Raid configuration information, Fault tolerance features – Dell PowerEdge RAID Controller 5i User Manual

Page 23

Advertising
background image

PERC 5 Features

21

RAID Configuration Information

Table 2-2 lists the configuration features for the PERC 5 controllers.

Fault Tolerance Features

Table 2-3 lists the features that provide fault tolerance to prevent data loss in case of a failed physical disk.

Table 2-2.

Features for RAID Configuration

Specification

PERC 5/E Adapter

PERC 5/i Adapter and 5/i Integrated

Number of virtual disks
supported

Up to 64 virtual disks per controller Up to 64 virtual disks per controller

NOTE:

The number of physical disks on a

controller is limited by the backplane on which
the card is attached.

Online RAID level migration

Yes

Yes

Disk roaming

Yes

Yes

No reboot necessary after
capacity expansion

Yes

Yes

User-specified rebuild rate

Yes

Yes

Table 2-3.

Fault Tolerance Features

Specification

Feature

Support for SMART

Yes

Support for Patrol Read

Yes

Physical disk failure detection

Automatic

Physical disk rebuild using hot spares

Automatic

Parity generation and checking (RAID 5 only)

Yes

Battery backup for controller cache to protect configuration data

Yes

a

Hot-swap manual replacement of a physical disk unit without bringing the system down

Yes

a

The PERC 5/i Adapter supports a battery backup unit (BBU) on selected systems only. For additional information,
see documentation that was shipped with the system.

Dell_PERC5_UG.book Page 21 Tuesday, February 13, 2007 6:02 PM