Dell PowerEdge RAID Controller 5i User Manual

Page 38

Advertising
background image

36

Hardware Installation and Configuration

3 Determine whether the dirty cache LED on the controller is illuminated.

•

If the LED is illuminated, replace the system cover, reconnect the system to power, turn on the
system, and repeat step 1 and step 2. See Figure 3-10.

NOTE:

The location of the PERC 5/i varies from system to system. See the Hardware Owner’s Manual

included with the system for specific information on where the PERC 5/i is located.

•

If the LED is not illuminated, continue with the next step.

Figure 3-10.

PERC 5/i Adapter Dirty Cache LED Location

4 Disconnect the data cables and battery cable from the PERC 5/i.
5 Remove any retention mechanism, such as a bracket screw, that might be holding the PERC 5/i in the

system, and gently lift the controller from the system’s PCI-E slot. See Figure 3-11.

dirty cache LED

bracket screw

PERC 5/i Adapter

memory module

Dell_PERC5_UG.book Page 36 Tuesday, February 13, 2007 6:02 PM