Wyse Datacenter Appliance XC for vWorkspace

9. By default, the containers you created in the Configuring Nutanix Storage Pool and Containers

section will be present. Select each file share path listed and click Remove to remove file shares.

Figure 43 Remove File Shares

10. Also, by default, the file share path will contain the FQDN of the host. Because of an apparent

bug in SCVMM, you must specify a placement path on each host that contains only the host
name in order for ODX Fast File Copy to work properly. If you specify the default path using the
FQDN, SCVMM will fall back to using BITS for copying the virtual disk files which will result in
much slower provisioning times. To specify a placement path that contains only the host name
in the UNC path, you must first add it to the file share storage paths for the MS Failover Cluster.
Click the Add button on the File Share Storage page.

11. In the Add File Share window, type the path to your compute container but do not use the

FQDN for the host―only use the host name.