Dell PowerEdge 1500SC User Manual

Page 10

Advertising
background image

connected, defective keyboard, or defective
keyboard/mouse controller (defective system
board).

persists, replace the system board. See "

Getting Help

," for instructions on

obtaining technical assistance.

Keyboard data line

failure

Keyboard stuck key

failure

Keyboard controller

failure

Defective keyboard/mouse controller (defective
system board).

Replace the system board. See "

Getting Help

," for instructions on obtaining

technical assistance.

Keyboard fuse has

failed

Defective keyboard.

Replace the keyboard.

Memory address line

failure at address,

read value expecting

value

Faulty or improperly seated memory modules or
defective system board.

Remove and reseat the memory modules. See "

Adding Memory

" in "Installing

System Board Options." If the problem persists, replace the memory modules.
If the problem persists, see "

Getting Help

," for instructions on obtaining

technical assistance.

Memory double word

logic failure at

address, read value

expecting value

Memory odd/even logic

failure at address,

read value expecting

value

Memory write/read

failure at address,

read value expecting

value

Memory allocation error

Faulty application program.

Restart the application program.

Memory parity interrupt

at address

Improperly seated or faulty memory modules.

Remove and reseat the memory modules. See "

Adding Memory

" in "Installing

System Board Options." If the problem persists, replace the memory modules.
If the problem persists, see "

Getting Help

," for instructions on obtaining

technical assistance.

Memory tests terminated

by keystroke

POST memory test terminated by pressing the
spacebar.

No action is required.

No boot device

available

Faulty diskette, diskette/tape drive subsystem,
hard drive, hard drive subsystem, or no boot disk
in drive A.

Replace the diskette or hard drive. See "

Installing Drives

." If the problem

persists, replace the system board. See "

Getting Help

," for instructions on

obtaining technical assistance.

No boot sector on hard-

disk drive

Incorrect configuration settings in System Setup
program, or no operating system on hard drive.

Check the hard drive configuration settings in the System Setup program. See
"Using the System Setup Program," in the User's Guide for instructions.

No timer tick interrupt

Defective system board.

Replace the system board. See "

Getting Help

," for instructions on obtaining

technical assistance.

Non-system disk or disk

error

Faulty diskette, diskette/tape drive subsystem,
or hard drive subsystem.

Replace the diskette or hard drive. See "

Installing Drives

." If the problem

persists, replace the system board. See "

Getting Help

," for instructions on

obtaining technical assistance.

Not a boot diskette

No operating system on diskette.

Use a bootable diskette

Processors with

different speeds

detected. System

halted!

Two different types of microprocessors are
installed.

Replace one of the microprocessors so that both are the same type. See
"

Adding or Replacing a Microprocessor

."

Read fault

Requested sector not

found

Faulty diskette, diskette/tape drive subsystem,
or hard drive subsystem.

Replace the diskette or hard drive. See "

Installing Drives

." If the problem

persists, replace the system board. See "

Getting Help

," for instructions on

obtaining technical assistance.

Reset failed

Improperly connected diskette/tape drive, hard
drive, or power cable.

Check that cables are securely connected. If the problem persists, replace the
system board. See "

Getting Help

," for instructions on obtaining technical

assistance.

ROM bad checksum =

address

Expansion card improperly installed or faulty.

Check that the expansion cards are fully seated. If problem persists, replace
the expansion card. See "

Expansion Cards

" in "Installing System Board

Options." If the problem persists, see "

Getting Help

," for instructions on

obtaining technical assistance.

Sector not found

Seek error

Defective sectors on diskette or hard drive.

Replace the diskette. If the problem persists, replace the hard drive. See
"

Installing Drives

." If the problem persists, see "

Getting Help

," for instructions

on obtaining technical assistance.

Seek operation failed

Faulty diskette or hard drive.

Replace the diskette. If the problem persists, replace the hard drive. See
"

Installing Drives

." If the problem persists, see "

Getting Help

," for instructions

on obtaining technical assistance.

Shutdown failure

Defective system board.

Replace the system board. See "

Getting Help

," for instructions on obtaining

technical assistance.

Time-of-day clock

stopped

Defective battery or faulty chip.

Replace the system battery. See "

Replacing the System Battery

" in "Installing

System Board Options."

Time-of-day not set -

please run SETUP

program

Incorrect Time or Date settings or defective
system battery.

Check the Time and Date settings. See "Using the System Setup Program," in
the User's Guide for instructions. If the problem persists, replace the battery.
See "

Replacing the System Battery

" in "Installing System Board Options." If

the problem persists, see "

Getting Help

," for instructions on obtaining

technical assistance.

Timer chip counter 2

failed

Defective system board.

Replace the system board. See "

Getting Help

," for instructions on obtaining

technical assistance.

Unexpected interrupt in

protected mode

Improperly seated memory modules or faulty
keyboard/mouse controller chip.

Remove and reseat the memory modules. See "

Adding Memory

" in "Installing

System Board Options." If the problem persists, replace the memory modules.
If the problem persists, see "

Getting Help

," for instructions on obtaining

technical assistance.