See "blinking fault, Led conditions" on – Dell PowerEdge C5230 User Manual
Page 16

14
Table 1-6. Blinking Fault LED Conditions
ID LED
Blue
Off
Normal status (by IPMI
Chassis Identify
command or System ID
Button)
Turn off the ID LED.
1. ipmitool raw 0x00 0x04
0x00
2. ipmitool raw 0x00 0x04
0x00 0x00
Solid On Identify the system
Turn on the ID LED.
1.ipmitool raw 0x00 0x04 0x3c
01
Blinking Identify the system with
interval
1. IPMI chassis identify
command without request
data ipmitool raw 0x00 0x04
2. IPMI chassis identify
command with only 1
parameter data ipmitool raw
0x00 0x04 0x3c (blink 60 sec)
3. IPMI chassis identify
command with 2 parameter
data ipmitool raw 0x00 0x04
0x3c 0x00 (blink 60 sec)
Heartbeat
LED
Green On
BMC is not ready
Blinking BMC is ready
Index
Sensor Name
Event Triggers
1
Memory Error
0: Correctable error
1: Uncorrectable error
5: Correctable ECC error logging limit reached
2
POST Error
Defined by BIOS and this sensor logged by BIOS.
3
PCIE Error
7: Bus correctable error
8: Bus Uncorrectable error
A: Bus fatal
Table 1-5. LED Status
LED
Color Status
Occurrence
Note