Setting the Magazines

This setting is used to report the number of storage elements and the element address to the SCSI host. This setting must

match the physical configuration in order for correct information to be reported. This setting only affects the information

reported to the SCSI host. This setting does not affect the access to magazine slots from the front panel or the Remote

Management Unit. Those interfaces are based on the physical configuration.

NOTE: The default setting of 'Left' must be reconfigured if the optional right magazine is installed. Host backup software

may also require reconfiguration if the loader was originally installed with only the default left magazine enabled.

When configured for Both magazines, the autoloader always reports 16 storage elements to the SCSI host. This allows the

removal and reinstallation of magazines without affecting what is reported to the host. When configured for Left or Right,

the autoloader will always report 8 storage elements to the SCSI host.

The element addresses vary depending on which magazine is configured. If Left or Right is selected, and both magazines are

physically installed, the front panel and the Remote Management Unit allow the user access to the other magazine, but the

SCSI host will not have access.

To set the Magazines option:

1. From any page, click the Configuration heading. The Configuration screen displays.

2. Scroll to Magazines. The Magazines options display.

A radio button appears after the currently enabled mode.

3. Do one of the following:

To leave the Magazines mode unchanged, press Esc.

To change the Magazines configuration, scroll to the setting you want for the autoloader, selecting the

appropriate check box, and then click submit. These settings include Both, Right, and Left.

The message This will require a power cycle and host backup software configuration change.
Enter To Continue

is displayed.

To continue with the change, press submit. The message Please Power cycle the tape autoloader and
reconfigure the host backup software app.

displays.

Setting the System Time

The system time is displayed by the Remote Management Unit and it is used internally for logging events and errors (see

"

Setting the Time

").

The autoloader must be reset after each power up. The time can be reset automatically if a time server is configured (see

"

Setting Network Options

"). Otherwise, the time must be set manually from the front panel or through the Remote

Management Unit. The time zone setting is not lost when powered off.

NOTE: Whether the autoloader is connected to a time server or not, if you want to include time changes for daylight

savings time, you must change the time zone manually.

To set the system time:

1. Using the first drop-down list next to Time Zone, select the number of hours difference between your local time and

Greenwich Mean Time (GMT).

NOTE: For example, if you live in Colorado, the time difference is –6 hours in the summer and –7 hours in the

winter.

2. Below the Time Zone field, select the current Month from the drop-down list.

3. In the Day field, type the current day of the month.

4. In the Year field, type the current year.

5. In the Hour text box, type the current hour in 24-hour format.

6. In the Minute text box, type the current minute.