Technical Specifications: Dell PowerVault 124T DLT VS160 Autoloader User's Guide

file:///T|/htdocs/stor-sys/124T/en/124tvs16/specs.html[12/5/2012 10:26:14 AM]

Interface

LVD ultra wide SCSI-2, 16-bit wide, 68-pin HD connector

Initialize element

status

90 seconds (typical)

Typical cycle time < 40 seconds. One cycle consists of moving a cartridge from the tape drive to a magazine slot, selecting

another magazine slot, and then moving the cartridge back to the tape drive. It does not include the

time that the tape drive takes to unload or load/calibrate.

Average load time

(after placing

cartridge in drive)

VS1 = 120 seconds (to BOT for previously written tape)

Average unload

time (from BOT)

VS1 = 25 seconds (from BOT)

Autoloader Environmental Specifications

Characteristic

Specification

Temperature Range (Dry Bulb)

Operating

+10º to +35ºC

Nonoperating

–40º to +65ºC

Temperature Variation

Operating

10ºC per hour

Nonoperating

20ºC per hour

Humidity

Operating

20% to 80% noncondensing

Nonoperating

10% to 90% noncondensing

Gradient

10% per hour without condensation

Wet Bulb

Operating

26ºC maximum

Advertising