Removing a sas controller daughter card – Dell POWEREDGE R805 User Manual

Page 32

Advertising
background image

 

5.

Attach one end of the interface cable to connector 0 on the SAS controller and the other end to the backplane SAS connector. See

Figure 3

-11

.

 

Figure 3-11. SAS Controller Daughter Card Cabling

 

6.

For battery-cached SAS RAID controllers, install the RAID battery. See

Installing a RAID Battery

.

 

Removing a SAS Controller Daughter Card

 

1.

Disconnect the SAS cable from the SAS controller daughter card.

 

2.

Press down on the blue release tab and push the SAS controller daughter card out of the sideplane connector. See

Figure 3

-10

.


 

3.

Remove the card tray from the chassis hooks and lift the card from the system.

 

4.

If applicable, remove the RAID battery from the battery holder.

1 SAS controller daughter card

2 sideplane

3 SAS controller daughter card socket

4 release tab

5 RAID battery connector (battery-cached SAS RAID controller only) 6 cutout

7 SAS cable (1)

8 SAS connector(s) (1 or 2) (only SAS 0 used)

NOTE:

Be sure to connect the cable according to the connector labels on the cable. The cable is not operational if reversed.

1 SAS controller daughter card

2 SAS 0 connector

3 SAS_A connector (below BKPLN connector) 4 SAS cable (1)

Advertising