Troubleshooting power supplies, Troubleshooting system cooling problems – Dell POWEREDGE R805 User Manual

Page 77

Advertising
background image

4.

Enter the System Setup program.

If the date and time are not correct in the System Setup program, replace the battery. See

System Battery

.

If the problem is not resolved by replacing the battery, see

Getting Help

.

 

Troubleshooting Power Supplies

 

Problem

l

 

System-status indicators are amber.

l

 

Power-supply fault indicators are amber.

l

 

Front-panel status LCD indicates a problem with the power supplies.

 

Action

 

 

1.

Run the appropriate online diagnostics test. See

Using Server Administrator Diagnostics

.


 

2.

Locate the faulty power supply.

The power supply's fault indicator is lit. See

Power Indicator Codes

.

Remove the faulty power supply. See

Removing a Power Supply

.

 

3.

Ensure that the power supply is properly installed by removing and reinstalling it. See

Replacing a Power Supply

.

 

4.

Check the indicators to see if the problem is resolved. If not, remove the faulty power supply. See

Removing a Power Supply

.


 

5.

Install a new power supply. See

Replacing a Power Supply

.

If the problem persists, see

Getting Help

.

 

Troubleshooting System Cooling Problems

 

Problem

l

 

Systems management software issues a fan-related error message.

 

Action

Ensure that none of the following conditions exist:

l

 

Ambient temperature is too high.

l

 

External airflow is obstructed.

l

 

Cables inside the system obstruct airflow.

l

 

An individual cooling fan has failed. See

Troubleshooting a Fan

.

 

NOTE:

Some software may cause the system time to speed up or slow down. If the system seems to operate normally except for the time kept in the

System Setup program, the problem may be caused by software rather than by a defective battery.

CAUTION:

Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as

authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not
authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

NOTICE:

You can hot-plug the power supplies. One power supply must be installed for the system to operate. The system is in the redundant mode

when two power supplies are installed. Remove and install only one power supply at a time in a system that is powered on. Operating the system for
extended periods of time with only one power supply installed, without a power supply blank installed, can cause the system to overheat.

NOTE:

After installing a power supply, allow several seconds for the system to recognize the power supply and to determine if it is working

properly. The power indicator turns green to signify that the power supply is functioning properly. See

Power Indicator Codes

.