on a component that resides in the specified slot.

If the problem persists, the riser card or system board is faulty. See

Getting

Help

.

E1714 Unknown Err

The system BIOS has determined that there has
been an error in the system, but is unable to
determine its origin.

See

Getting Help

.

E171F PCIE Fatal Err

B## D## F##

The system BIOS has reported a PCIe fatal error
on a component that resides in PCIe configuration
space at bus ##, device ##, function ##.

Remove and reseat the PCIe expansion cards. If the problem persists, see

Troubleshooting Expansion Cards

.

PCIE Fatal Err

Slot #

The system BIOS has reported a PCIe fatal error
on a component that resides in the specified slot.

Reinstall the expansion-card riser. See

Expansion-Card Risers

.

If the problem persists, the riser card or system board is faulty. See

Getting

Help

.

E1810 HDD ## Fault

The SAS subsystem has determined that hard
drive ## has experienced a fault.

See

Troubleshooting a Hard Drive

.

E1811 HDD ## Rbld Abrt

The specified hard drive has experienced a rebuild
abort.

See

Troubleshooting a Hard Drive

. If the problem persists, see your RAID

documentation.

E1812 HDD ## Removed

The specified hard drive has been removed from
the system.

Information only.

E1914 DRAC5 Conn2 Cbl

DRAC 5 cable is missing or disconnected.

Reconnect the cable. See

Installing a RAC Card

.

E1915 IO55 HTSink

Missing

MCP55 Htsink

Missing

Heatsink sensor reports that the chipset IO55
heatsink is missing.

Heatsink sensor reports that the chipset MCP
heatsink heatsink is missing.

See

Getting Help

.

E1A12 PCI Rsr Missing

One or all of the PCIe risers is missing, preventing
the system from powering on.

Reinstall the missing riser card(s).

E1A14 SAS Cable A

SAS cable A is missing or bad.

Reseat the cable. If the problem persists, replace cable. See

SAS Controller

Daughter Card

.

E1A15 SAS Cable B

SAS cable B is missing or bad.

Reseat the cable. If the problem persists, replace cable. See

SAS Controller

Daughter Card

.

E1A1C LOM Mezz Missing

LOM daughter card is missing.

Install or reseat the LOM daughter card. If the problem persists, replace the
card. See

Getting Help

.

E1B01 USB# Overcurrent

Device plugged in the specified USB port caused
an overcurrent condition.

Reseat the device cable. If the problem persists, replace or remove the
device.

E2010 No Memory

No memory is installed in the system.

Install memory. See

Installing Memory Modules

.

E2011 Mem Config Err

Memory detected, but is not configurable. Error
detected during memory configuration.

See

Troubleshooting System Memory

.

E2012 Unusable Memory

Memory is configured, but not usable. Memory
subsystem failure.

See

Troubleshooting System Memory

.

E2013 Shadow BIOS Fail

The system BIOS failed to copy its flash image into
memory.

See

Troubleshooting System Memory

.

E2014 CMOS Fail

CMOS failure. CMOS RAM not functioning properly. See

Getting Help

.

E2015 DMA Controller

DMA controller failure.

See

Getting Help

.

E2016 Int Controller

Interrupt controller failure.

See

Getting Help

.

E2017 Timer Fail

Timer refresh failure.

See

Getting Help

.

E2018 Prog Timer

Programmable interval timer error.

See

Getting Help

.

E2019 Parity Error

Parity error.

See

Getting Help

.

E201A SIO Err

SIO failure.

See

Getting Help

.

E201B Kybd Controller

Keyboard controller failure.

See

Getting Help

.

E201C SMI Init

System management interrupt (SMI) initialization
failure.

See

Getting Help

.

E201D Shutdown Test

BIOS shutdown test failure.

See

Getting Help

.

E201E POST Mem Test

BIOS POST memory test failure.

See

Troubleshooting System Memory

. If problem persists, see

Getting Help

.

E201F DRAC Config

Dell remote access controller (DRAC) configuration
failure.

Check screen for specific error messages.

Ensure that DRAC cables and connectors are properly seated. If problem
persists, see your DRAC documentation.

E2020 CPU Config

CPU configuration failure.

Check screen for specific error messages.

E2021 Memory Population

Incorrect memory configuration. Memory
population order incorrect.

Check screen for specific error messages. See

Troubleshooting System

Memory

.

E2022 POST Fail

General failure after video.

Check screen for specific error messages.

E2110 MBE DIMM # & #

One of the DIMMs in the set implicated by "# & #"
has had a memory multi-bit error (MBE).

See

Troubleshooting System Memory

.

E2111 SBE Log Disable

DIMM #

The system BIOS has disabled memory single-bit
error (SBE) logging, and will not resume logging
further SBEs until the system is rebooted. "#"
represents the DIMM implicated by the BIOS.

See

Troubleshooting System Memory

.

E2112 Mem Spare DIMM #

The system BIOS has spared the memory because
it has determined that the memory had too many
errors. "# & #" represents the DIMM pair
implicated by the BIOS.

See

Troubleshooting System Memory

.