Network-attached configurations – Dell POWERVAULT MD3620I User Manual

Page 20

Advertising
background image

20

Hardware Installation

Network-Attached Configurations

You can also cable the host servers to the RAID controller module iSCSI ports

through industry-standard 10G or 1G Ethernet switches. An iSCSI

configuration that uses Ethernet switches is frequently referred to as an IP

SAN. By using an IP SAN, the PowerVault MD3600i series storage array can

support up to 64 hosts simultaneously. This configuration supports either

single or dual path data configurations and either single or dual controller

modules.
Figure 2-6 shows up to 64 stand-alone servers attached (using multiple

sessions) to a single RAID controller module through a network. Hosts that

have a second Ethernet connection to the network allow two separate

physical paths for each host, which ensures full redundancy if one of the paths

fails. It is recommended you use two switches for more redundancy. However,

single switch configuration is also supported. Figure 2-7 shows how the same

number of hosts can be similarly attached to a dual RAID controller module

configuration.
Figure 2-8 shows up to 64 stand-alone servers attached (using multiple

sessions) to a single RAID controller module through a network using a 1G to

10G aggregation scheme. The NICs on the servers are 1G NICs and the

uplink ports on the 1G switches are 10G. Hosts that have a second Ethernet

connection to the network allow two separate physical paths for each host,

which ensures full redundancy if one of the paths fails. It is recommended you

use two switches for more redundancy. However, single switch configuration is

also supported.
Figure 2-9 shows how the same number of hosts can be similarly attached to a

dual RAID controller module configuration. Hardware redundancy is

achieved in this configuration, in case of any switch failure.

book.book Page 20 Thursday, July 18, 2013 5:39 PM

Advertising
This manual is related to the following products: