Appendix-manual configuration of iscsi, Appendix—manual configuration, Of iscsi – Dell POWERVAULT MD3620I User Manual

Page 55: Appendix—manual configuration of iscsi

Advertising
background image

Appendix—Manual Configuration of iSCSI

55

A

Appendix—Manual Configuration

of iSCSI

The following sections contain step-by-step instructions for configuring

iSCSI on your storage array. However, before beginning, it is important to

understand where each of these steps occur in relation to your host server or

the storage array environment.
Table A-1 shows each iSCSI configuration step and where it occurs.

Table A-1. Host Server Vs. Storage Array

This Step is Performed on the Host Server
Using the Microsoft or Linux iSCSI Initiator

This Step is Performed on the Storage
Array Using MD Storage Manager

1

Discover the storage array.

2

Configure the iSCSI ports on the

storage array.

3

Perform target discovery from the iSCSI

initiator.

4

Configure host access.

5

(Optional) Configure

Challenge

Handshake Authentication

Protocol (

CHAP) authentication on

the storage array.

6

(Optional) Configure CHAP

authentication on the host server.

7

Connect to the storage array from the

host server.

8

(Optional) Set up in-band

management.

book.book Page 55 Thursday, July 18, 2013 5:39 PM

Advertising
This manual is related to the following products: