background image

Drive-Status Indicator Pattern

(RAID Only)

Condition

Blinks green, amber, and turns
off

Predicted drive failure

Blinks amber four times per
second

Drive failed

Blinks green slowly

Drive rebuilding

Steady green

Drive online

Blinks green three seconds,
amber three seconds, and
turns off six seconds

Rebuild aborted

Power Supply and Cooling Fan Features

The MD3800f and MD3820f Series storage array includes two integrated, hot-swappable power supply/
cooling fan modules. Both modules must be installed to ensure proper cooling. The system requires at
least one of the cooling fans to function, to avoid overheating.
A power supply/cooling fan module can be replaced without powering down the system. For information
on removing and installing the modules, see

Power Supply/Cooling Fan Module

.

Power Indicator Codes and Features

Figure 6. Power Indicator Codes and Features

Item

LED Type

Icon

Description

1

DC power

The LED lights green when the DC output voltage is within

the limit.

11

Advertising