Dell PowerVault MD3820f User Manual

Page 48

Advertising
background image

Back-Panel Connectors (Per RAID Controller

Module)

Serial connector (debug port)

One mini-USB port

NOTE: For technical support use only.

Management Ethernet connector

One 100/1000 Mbps Ethernet connection for out-of-
band management of the enclosure (MGMT)

Power

AC power supply (per power supply)

Wattage

600 W

Heat dissipation (maximum)

NOTE: Heat dissipation is calculated
using the power supply wattage
rating. The heat dissipation values are
for the entire system which includes
chassis and two controllers.

100 W

Voltage

NOTE: This system is also designed to
be connected to IT power systems
with a phase to phase voltage not
exceeding 230 V.

100–220 V AC, (8.6 A-4.3 A)

Battery

6.6 V DC, 1100 mAh, 7.26 W Lithium ion battery

Environmental

NOTE: For additional information about environmental measurements for specific system
configurations, see dell.com/environmental_datasheets.

Temperature

Operating

Continuous operation: 10 °C to 35 °C (50 °F to 95 °F) at
20% to 80% relative humidity (RH), with 26 °C
maximum dew point. De-rate maximum allowable dry
bulb temperature at 1 °C/300 m (1 °F per 550 ft) above
900 m (2952.75 ft).

NOTE: For information on supported expanded
operating temperature range and configurations,
see the Owner's Manual at dell.com/
powervaultmanuals.

Storage

–40 °C to 65 °C (–40 °F to 149 °F) with a maximum
temperature gradation of 20 °C per hour

Relative humidity